AE340A SeriesCT/VT connectionTHREE-PHASE CT/VT SMART METER

Three-Phase Smart Meter, CT/VT Connection

The AE340 A Series for CT/VT connection is a three-phase four-wire smart meter for indirect connection through current and voltage transformers, in the new AetherEdge™ enclosure, with class 0.2S active energy measurement. A plug-in 3G cellular module provides remote communication with the head-end system over DLMS/COSEM. The values on this page come from the Rev1.0 user manual, a draft for approval.

Three-phase four-wireCT/VT connectionClass 0.2SRev1.0 draft
SPECIFICATIONS
ConnectionThree-phase four-wire, indirect connection through CTs and VTs
Remote communicationPlug-in 3G cellular module (GSM/GPRS 2G, UMTS/HSPA 3G)
Nominal voltage (Un)3 × 57.7/100 V
Voltage range (phase to neutral)57.7 V − 20 % to + 15 %
Frequency50 Hz ± 5 %
Basic current (In)5 A
Maximum current (Imax)10 A
Starting current0.001 × Inom
Short circuit (< 10 ms)20 × Imax
Active energyClass 0.2S · IEC 62053-22
Reactive energyAccuracy class being confirmed — not published in this draft
Pulse constant (LED)10000 imp/kWh · 10000 imp/kvarh
Operating temperature−40 °C to +70 °C
Storage temperature−40 °C to +85 °C
Insulation strength4 kV, protection class II
Degree of protectionIP54
DisplayLCD with 9 digits; auto-scroll, manual and power-off display modes
ButtonsManual display button; sealed demand-reset button
Humidity≤ 95 %
Real-time clock0.5 s/day at reference temperature
BackupReplaceable battery
CaseGlass-fibre polycarbonate; screw-fixed (BS) base and cover; long terminal cover with two sealing screws
Overall dimensions W × H × D170 × 261.5 × 83.8 mm
Fixing centres190 mm vertical · 150 mm horizontal
INQUIRE ABOUT THIS PRODUCT ↗← BACK TO EDGE-3P

Source: AE340 A Series CT/VT-connection user manual, Rev1.0 draft for approval (4 November 2026). The values are draft design information, not test or certification results; values under review are not published.

Key features

  • Indirect three-phase four-wire connection through current and voltage transformers.
  • Active energy measurement to class 0.2S (IEC 62053-22); four-quadrant measurement of active and reactive energy.
  • Plug-in 3G cellular module (GSM/GPRS 2G and UMTS/HSPA 3G) for remote communication over DLMS/COSEM, with encrypted communication data.
  • Measurement of grid parameters such as real-time power, voltage, current and power factor.
  • Local and remote software upgrade; optical port with direct HDLC or IEC 62056-21 mode E.

Meter functions

Measurement

  • Active energy import and export in kWh and reactive energy in all four quadrants; average voltage, current and power values.

Demand

  • Current, average and maximum demand with a demand period of 60, 300, 900, 1800 or 3600 s; maximum-demand reset.

Instantaneous values

  • Instantaneous values such as voltage, current, power and power factor.

Time of use and clock

  • Time-of-use tariff management; quartz-crystal real-time clock with Gregorian calendar, kept running by the battery during a power failure.

Display and LEDs

  • 9-digit LCD with auto, manual and power-down display modes; LED indications.

Billing and load profiles

  • Billing period closed on any selected date; billing registers cannot be reset to zero; billing profiles and load profiles stored in the meter.

Events and alarms

  • Self-diagnostic event log with time stamps; recorded signals (alarms); all meter actions are logged and can be read locally or remotely.

Security

  • Encryption of communication data and DLMS/COSEM security set-up.

Firmware upgrade

  • Local upgrade over the optical (IR) port and remote upgrade over the communication module.

Communication

  • Optical port with direct HDLC or IEC 62056-21 mode E; slot for a plug-and-play cellular module.

Backup power and memory

  • Lithium cell for the clock, cover-opening recording and display while the mains supply is off; low-battery alarm; terminals for an auxiliary AC power supply; basic parameters stored in non-volatile memory with date and time stamps.

Electrical immunity (draft design values)

Electrostatic discharge
Contact 8 kV · air 15 kV
HF electromagnetic field
80 MHz to 2 GHz, 10 V/m with load · 30 V/m without load
Fast transient burst
4 kV
Radio interference
CISPR 22, class B equipment
Impulse voltage
6 kV
Current impulse
At least 5 kA, 8/20 µs
AC voltage
Main circuit 4 kV · auxiliary contact 2 kV
Pollution degree
III

Standards referenced

These standards are referenced in the Rev1.0 draft manual. They are not certification claims or test results. Contact Archai for applicable approvals for your configuration.

  • IEC 62053-22 — Static meters for active energy (classes 0.1S, 0.2S and 0.5S).
  • IEC 62053-24 — Static meters for fundamental component reactive energy.
  • IEC 62052-11 — Metering equipment: general requirements, tests and test conditions.
  • IEC 61010-1 — Safety requirements for electrical equipment for measurement, control and laboratory use.
  • EN 50065-1 — Signalling on low-voltage electrical installations, 3 kHz to 148.5 kHz.
  • IEC 62056 series, DLMS UA 1000-1 and DLMS UA 1000-2 — DLMS/COSEM data exchange, OBIS and interface classes.
  • IEEE 802.15.4-2020 — Low-rate wireless networks.

Dimensions

AE340 A Series, CT/VT connection — dimension drawing
Dimension drawing from the Rev1.0 draft manual (Figure 1.7-1), in millimetres: 170 × 261.5 × 83.8 mm (W × H × D); fixing centres 190 mm and 150 mm. The A Series AE340 variants share this enclosure drawing.
View full-size drawing ↗